Temperature rise from thermal resistance
How hot a component gets above its surroundings for a given heat loss.
Heat flowing through a thermal resistance behaves like current through an electrical one: temperature difference plays the role of voltage. Heatsink datasheets give R_th in K/W; add the resistances in series from junction to air.
The same idea, with a thermal capacitance C_th added, gives the first-order thermal model used for battery cells and power electronics: the temperature approaches T_ambient + R_th·P with time constant τ = R_th·C_th.
Variables & units
| Symbol | Quantity | Unit here | SI dimension |
|---|---|---|---|
| Temperature rise | K | K [Θ] | |
| Thermal resistance | K/W | m⁻²·kg⁻¹·s³·K [L^-2 M^-1 T^3 Θ] | |
| Heat dissipated | W | m²·kg·s⁻³ [L^2 M T^-3] |
Rearranged
| Solve for | Formula | Dimensions check |
|---|---|---|
| Temperature rise | ✓ K | |
| Thermal resistance | ✓ m⁻²·kg⁻¹·s³·K | |
| Heat dissipated | ✓ m²·kg·s⁻³ |
The dimension of every rearrangement is computed from the dimensions of its variables by our expression engine — so a typo in a formula on this page would show up here in red.
Assumptions
- Steady state (after several time constants).
- R_th constant — in reality it depends on airflow and temperature.
Example
A regulator dissipating 5 W on a 2 K/W heatsink runs 10 K above the air around it.
Connected
Pressure, force, torque, power, energy, temperature, viscosity, flow and 12 more engineering quantities.
Steady heat flow through a flat wall.
Power delivered to a load equals voltage times current.
Most engineering knowledge is published as static PDFs that can't be checked, changed or built on. It's time to publish the model, not just a picture of it.
We derive the lumped thermal model used in many battery management systems, show how its two parameters set the steady-state temperature rise and the response time, and work through an illustrative cylindrical-cell example with Ohmic heating of 2 W. Steady state is reached after about five time constants; with an illustrative thermal resistance of 8 K/W and heat capacity of 70 J/K the cell settles 16 K above ambient with a time constant of 560 s. The model ignores internal temperature gradients and entropic heat, which we discuss as limitations.
A 2025 preprint fits a simple equivalent-circuit thermal model with ordinary least squares, using data from a single cycle — and tests it on NASA, MIT and Oxford battery datasets.