Heat conduction (Fourier's law)
Steady heat flow through a flat wall.
Playground · Heat conduction (Fourier's law)
solve for
Heat flow
384 W
Plot heat flow against
Heat flows from hot to cold at a rate proportional to the conductivity, the area and the temperature gradient. Insulation works by having a very low k.
Variables & units
| Symbol | Quantity | Unit here | SI dimension |
|---|---|---|---|
| Heat flow | W | m²·kg·s⁻³ [L^2 M T^-3] | |
| Thermal conductivity | W/(m·K) | m·kg·s⁻³·K⁻¹ [L M T^-3 Θ^-1] | |
| Area | m² | m² [L^2] | |
| Temperature difference | K | K [Θ] | |
| Thickness | mm | m [L] |
Rearranged
| Solve for | Formula | Dimensions check |
|---|---|---|
| Heat flow | ✓ m²·kg·s⁻³ | |
| Thermal conductivity | ✓ m·kg·s⁻³·K⁻¹ | |
| Area | ✓ m² | |
| Temperature difference | ✓ K | |
| Thickness | ✓ m |
The dimension of every rearrangement is computed from the dimensions of its variables by our expression engine — so a typo in a formula on this page would show up here in red.
Assumptions
- Steady state, one-dimensional conduction through a homogeneous slab.
- Surface (convective) resistances neglected — in real walls they add to the total thermal resistance.
Example
12 m² of 25 mm mineral wool (k ≈ 0.04 W/m·K) with 20 K across it: Q = 0.04 × 12 × 20 / 0.025 = 384 W.