Battery management systems need to know how hot a cell is getting, but full electrochemical-thermal models are too heavy to run on a small microcontroller. Chowdhury and Lu propose a lighter route: treat the cell's heat flow like an electric circuit.
The model
The surface temperature T_s follows a first-order thermal circuit with thermal resistance R_T, thermal capacitance C_T, ambient temperature T_a and internal heat generation h:
Discretised with a sampling step, it becomes a simple recursion, with ε set by the time constant:
The heat generation is approximated from measurable quantities — current I, terminal voltage V and a polynomial in state of charge that stands in for the open-circuit voltage:
The trick: make it linear in the parameters
Substituting (3) into (2) gives an expression that is linear in the unknown parameters, so they can be identified with ordinary least squares from one cycle of data — no iterative optimisation. The authors call this one-shot identification.
What they tested
The model was validated on public NASA, MIT and Oxford battery datasets under different degradation states and ambient conditions.
Try the physics
At steady state, (1) reduces to a temperature rise ΔT = R_T · h. Explore it:
For a worked, step-by-step version of this model with illustrative numbers, read our technical paper on a first-order thermal model of a battery cell.
Use it
Discussion
Technical questions and corrections are welcome. Comments are signed and checked before they appear.
No comments yet.
Sign in to add a typed review comment. Reviews are signed with your name.