EPREVAEngineer Paper
ProjectElectricalEnergy

Demo project: a solar-powered UV-C water purifier for a field station

Shows how a project log works on Engineer Paper: goal, bill of materials, live calculations, and a build log that records what failed and why.

Demo. Created by Engineer Paper to show how this format works. It is not a real person's project and not original research.
small 12 V diaphragm pump and clear filter housing, glowing UV-C lamp in a transparent pipe or sleeve, 12 V battery with solar charge controller, measuring jug and flow/stopwatch setup on a bench, evidence of the start-up current test, e.g. clamp meter or soft-start module
AI-generated image

Goal

Treat 200 litres of pre-filtered rainwater a day for a small field station, using a 12 V solar system and a UV-C lamp, with no grid connection.

Components

Bill of materials
QtyPartNote
112 V, 6 W UV-C lamp in a stainless reactorsized for about 4 L/min
112 V diaphragm pump, 4 L/minself-priming
1100 W solar panelsouth-facing, 30° tilt
112.8 V, 50 Ah LiFePO4 batterywith BMS
110 A MPPT charge controller
15 µm sediment filterbefore the UV reactor

Calculations

Pump (≈ 36 W) and lamp (6 W) run together. Treating 200 L at 4 L/min takes 50 minutes a day — about 35 Wh. Check the battery margin:

Toolbox · Battery capacity & runtime calculatorOpen full tool →
Loading tool…

Electrical power of the load at 12 V:

Playground · Electrical power
solve for
Power
59.8 W
Plot power against
26000.11,000 V

Build log

Day 1Progress
Bench test of the reactor

Lamp and pump wired to a bench supply. Flow measured at 3.8 L/min with the filter fitted.

Day 3What failed and why
Pump stalled at start-up after a cold night

The pump drew roughly 9 A for a moment at start-up and the BMS tripped its over-current protection. Lesson: the start-up current of a diaphragm pump can be several times its running current. Fix: soft-start module and a BMS with a higher peak rating.

Day 5Revision
Soft start added, lamp warm-up delay

Added a soft-start and a 60-second delay so the UV lamp reaches full output before water flows.

Day 9Test
Flow and dose check

Flow steady at 3.9 L/min. A real build would verify the UV dose with a calibrated sensor and lab tests of the water — this demo does not.

Day 12Result
Runs a full day on solar

Battery state of charge never fell below 70 % over a sunny day.

Use it

Discussion

Technical questions and corrections are welcome. Comments are signed and checked before they appear.

No comments yet.

Sign in to add a typed review comment. Reviews are signed with your name.

More projects