EPREVAEngineer Paper
ENERGYNewsMaterialsEnergySemiconductors

Dual silicon oxide barrier lifts TOPCon solar cell efficiency by 0.07 points

In an industrial batch of 966 cells, average conversion efficiency rose from 27.15% to 27.22% after post-plasma oxidation was extended to 100 seconds.

silicon wafer with polysilicon/tunnel oxide layers, gloved hands or cleanroom environment, PECVD or oxidation process equipment in soft background
AI-generated image

Researchers at Nanchang Hangkong University in China have developed a dual silicon oxide (SiOₓ) diffusion barrier strategy for tunnel oxide passivated contact (TOPCon) solar cells, combining post-plasma oxidation with tunnel oxide optimisation to control the depth distribution of electrically active phosphorus and the microstructure of polysilicon, according to a paper published in Solar Energy. The research team included scientists from Chinese PV manufacturer ZQi Solar Technology.

Corresponding author Wenhao Chen told pv magazine that conventional industrial TOPCon optimisation mainly adjusts the total phosphorus dose or tunnel oxide quality without independently controlling the position of the electrically active phosphorus peak within polysilicon. Phosphorus accumulation at the surface increases parasitic optical absorption without further reducing contact resistance, Chen said, creating a trade-off between contact and optical losses in mass-produced cells.

According to the researchers, inward-diffusing oxygen induces depth-selective dopant deactivation through the formation of electrically inactive phosphorus–oxygen complexes, rather than physically redistributing phosphorus atoms. Extending post-plasma oxidation to 100 seconds shifted the activated phosphorus peak from the poly-Si surface to a depth of approximately 50 nm, which the researchers say closely matches the silver paste burn-off depth during screen-printing and co-firing.

Five oxidation durations were tested: 0, 66, 85, 100 and 120 seconds, with 66 seconds representing the conventional industrial process.

Increasing oxidation from 66 to 100 seconds shifted the electrically active phosphorus peak from approximately 20 nm to 50 nm below the polysilicon surface; further oxidation to 120 seconds caused excessive phosphorus deactivation and degraded passivation quality. With the optimised bottom tunnel oxide barrier, the team reports an implied open-circuit voltage of 742.4 mV. Contact resistivity fell from 1.54 mΩ cm² to 1.00 mΩ cm², although the researchers could not attribute the improvement solely to the shift in the phosphorus peak.

The researchers concluded that the optimised oxidation process offers a promising route to improving industrial TOPCon performance, although the individual contributions of dopant deactivation, structural changes and optical effects remain difficult to isolate. Chen said the process modification can be implemented on existing PECVD production lines.

Key facts

  • 0.07 percentage points: absolute efficiency gain in industrial batch of 966 TOPCon cells, from 27.15% to 27.22%
  • 100 seconds: optimised post-plasma oxidation duration, versus 66 seconds conventional
  • 50 nm: depth of activated phosphorus peak after 100-second oxidation, versus approximately 20 nm at 66 seconds
  • 1.00 mΩ cm²: rear contact resistivity after optimisation, down from 1.54 mΩ cm²
  • 742.4 mV: implied open-circuit voltage with optimised bottom tunnel oxide barrier

Sources

  1. Dual-oxide diffusion barrier boosts efficiency of mass-produced TOPCon solar cells by 0.07 percentage points — pv magazine

Other news outlets are named as sources but not linked.

Discussion

Technical questions and corrections are welcome. Comments are signed and checked before they appear.

No comments yet.

Sign in to add a typed review comment. Reviews are signed with your name.

More news